• Port Size: 1/2 (F) NPT
• Maximum Airflow at 100 PSI: 61 SCFM
• Maximum Working Pressure: 250 PSI
• Pressure Range: 0-60 PSI
• Working Temperature: 0 to 80 °C
• Filtration: 5 microns
• Drain: Automatic
• Bowl Capacity: 130.1 ml
• Pressure Gauge Port Size: 1/4 (F) NPT
Material(s):
• Body Material(s): Zinc (Aluminum for 2 NPT)
• Bowl Type: Zinc
• High flow design
• Space-saving integrated filter/regulator design
• Push-pull tamper-proof adjusting knob
• Removes contaminants down to 5 microns in size
• Removes water through centrifugal force
• Provides quick response to pressure adjusments
• Maintains constant downstream pressure
• Automatic drain available
WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application
WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools requires different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application
Also available with a 5 micron element: add sufix .05
• Port Size: 1/2 (F) NPT
• Maximum Airflow at 100 PSI: 61 SCFM
• Maximum Working Pressure: 250 PSI
• Pressure Range: 0-60 PSI
• Working Temperature: 0 to 80 °C
• Filtration: 5 microns
• Drain: Automatic
• Bowl Capacity: 130.1 ml
• Pressure Gauge Port Size: 1/4 (F) NPT
Material(s):
• Body Material(s): Zinc (Aluminum for 2 NPT)
• Bowl Type: Zinc
• High flow design
• Space-saving integrated filter/regulator design
• Push-pull tamper-proof adjusting knob
• Removes contaminants down to 5 microns in size
• Removes water through centrifugal force
• Provides quick response to pressure adjusments
• Maintains constant downstream pressure
• Automatic drain available
WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application
WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools requires different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application
Also available with a 5 micron element: add sufix .05