• Port Size: 1/2 (F) NPT
• Maximum Airflow at 100 PSI: 84 SCFM
• Maximum Working Pressure: 150 PSI
• Pressure Range: Standard: 5-125 PSI
• Options: 5-30 PSI • 5-60 PSI
• Working Temperature: 5 to 60 °C
• Filtration: Filter: 5 microns • Coalescing Filter: 0.01 micron
• Drain: Semi-automatic, 8 mm O.D. tubing
• Bowl Capacity: Filter/regulator: 45 ml • Coalescing Filter: 45 ml
• Pressure Gauge Port Size: 1/4 (F) NPT
Material(s):
• Body Material(s): Die cast Aluminum
• Bowl Type: Polycarbonate with steel guard
• Bowl Guard: Steel
• Regulation Type: Relieving
• Filter Element: Coalescing filter, Borosilicate, 0.01 micron
• Deflector & Spinner: ABS
• O-Rings & Seals: EPDM rubber
• Regulator Cap: Die cast Aluminum
• Regulator Adjusting Knob: Reinforced nylon
• Diaphragm: EPDM rubber
• Poppet Valve: Brass and rubber
• Regulator Spring: Stainless steel
• Compact design with space saving integrated filter/regulator
• Accurate pressure control with little drift
• Removable locking push-pull adjusting knob
• Standard semi-automatic drain requires a simple tug of the ring to drain
• High performance filter that removes solid particles and oil and water aerosols greater than 0.01 micron, of which 99.97 % of those between 0.3 and 0.6 Micron
• Pressure gauge, piping adapters and mounting bracket included
WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application
WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools requires different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application
Rod for Element 400-450 F/R Semi Auto Poly
Element 0.01 mic for 400 FC
Diaphragm + Piston for 400 F/R
Poly Bowl w/Guard & Drain 400-450-500 F,FC,F/R
Element 5 mic for 400-450 F, F/R Semi Auto
5-125 PSI Spring for 400-450 R, F/R
Cap Knob for R, F/R 400-450-500
Mounting Nut for R, F/R 400-450-500
• Port Size: 1/2 (F) NPT
• Maximum Airflow at 100 PSI: 84 SCFM
• Maximum Working Pressure: 150 PSI
• Pressure Range: Standard: 5-125 PSI
• Options: 5-30 PSI • 5-60 PSI
• Working Temperature: 5 to 60 °C
• Filtration: Filter: 5 microns • Coalescing Filter: 0.01 micron
• Drain: Semi-automatic, 8 mm O.D. tubing
• Bowl Capacity: Filter/regulator: 45 ml • Coalescing Filter: 45 ml
• Pressure Gauge Port Size: 1/4 (F) NPT
Material(s):
• Body Material(s): Die cast Aluminum
• Bowl Type: Polycarbonate with steel guard
• Bowl Guard: Steel
• Regulation Type: Relieving
• Filter Element: Coalescing filter, Borosilicate, 0.01 micron
• Deflector & Spinner: ABS
• O-Rings & Seals: EPDM rubber
• Regulator Cap: Die cast Aluminum
• Regulator Adjusting Knob: Reinforced nylon
• Diaphragm: EPDM rubber
• Poppet Valve: Brass and rubber
• Regulator Spring: Stainless steel
• Compact design with space saving integrated filter/regulator
• Accurate pressure control with little drift
• Removable locking push-pull adjusting knob
• Standard semi-automatic drain requires a simple tug of the ring to drain
• High performance filter that removes solid particles and oil and water aerosols greater than 0.01 micron, of which 99.97 % of those between 0.3 and 0.6 Micron
• Pressure gauge, piping adapters and mounting bracket included
WHERE TO INSTALL A FILTER
Install the filter as far as possible from the compressor to allow the compressed air to cool and water vapors to condense. Removal of water in liquid form is more effective than removing water which is vapor form.
Install the filter closest to the tool and before the lubricator and regulator
Always install the filter with the arrows pointing to the tool or application
WHERE TO INSTALL A REGULATOR
Install the regulator on each pipe where applications and air tools requires different working pressure
Always install the regulator downstream of a filter and upstream of a lubricator
Can be installed vertically or horizontally
Always install regulator with the arrows pointing to the tool or application